Nano Liquid Photonic Coating™ Reflector · Technical Specification Sheet
Evidence status: Values below are manufacturer-reported internal summaries. Independent third-party validation is pending; original instrument exports and complete raw tables are not currently publicly downloadable.
Scope: These values are manufacturer-reported summaries from the evaluation program conducted over more than 36 months. This sheet reports technical values; it does not reproduce the full study protocol or original instrument exports. See the Testing Methodology for procedures and the Testing Data Repository for downloadable files and availability.
Instrument listed: Apogee MQ-610. Lamp listed: Philips MasterColor 250W / 830 CMH. Average reported over a 2 × 2 ft area. Units: µmol·m⁻²·s⁻¹.
| Lamp-to-sensor height | Center PPFD | 2 × 2 ft average |
|---|---|---|
| 12 in | 1,040 | 824 |
| 18 in | 720 | 611 |
| 24 in | 510 | 426 |
| Reflector condition | Band / measure | Reported reflectance |
|---|---|---|
| Bare aluminum | Visible | 92.1% |
| Bare aluminum | PAR | 94.0% |
| Nano Liquid Photonic Coating™ | Visible | 97.4% |
| Nano Liquid Photonic Coating™ | PAR | 98.7% |
| Nano Liquid Photonic Coating™ | Blue band | 99.2% |
| Nano Liquid Photonic Coating™ | Red band | 99.3% |
| Measure | Reported value | Evidence note |
|---|---|---|
| Spectral intensity change at reflector exit | Blue +22.4%; green +4.2%; red +28.7%; far red +6.1%; UV +3.5% | Manufacturer-reported; source exports not attached |
| Fixture surface temperature | Approximately 45°C at steady state in a 24°C chamber | Thermal records and camera settings not published |
| Burn-in observation | 72 hours; no observed discoloration, delamination, or reflectance drop | Manufacturer-reported observation |
| Nano-cluster size | 23–79 nm | Reported microscopy range; source files not published |
| Beam spill reduction | 31% | Manufacturer-reported comparison against an uncoated reflector |
| Measurement uncertainty | ±3% | Protocol figure; supporting uncertainty budget is not yet public |
Results depend on lamp, reflector geometry, distance, measurement grid, instrument calibration, and room conditions. Published summaries do not include sufficient raw observations or uncertainty calculations for independent reproduction. These values should be treated as manufacturer-reported until supporting records and independent validation are published.